RGMV
PRODUCT NOTICE
Relay cover change
For more information click here
- Monostable plug-in trip relays, fast acting, with 4 contacts, 10 A
- 2 models for various contact configurations
- Switching time < 8ms, bounces included
- Solid and rugged construction for intensive duty
- High electrical life expectancy and exceptional endurance
- Self-cleaning knurled contacts
- Wide variety of configurations and customizations
- Wide range of sockets
- Transparent cover, pull-out handle
- Positive mechanical keying for relay and socket
RGM series trip relays are highly reliable products providing top performance, suitable for applications in particularly harsh and unsettled environments, such as high voltage electricity distribution stations and medium voltage substations:
The typical applications are:
- for interfaces between protections or automation systems and HV / MV breakers, for alarm transmission and very rapid trip operations
- multiplication of trip contacts in minimal time intervals
2 models: RGMV12 with 4 changeover contacts and RGMV13 with 4 N.O. contacts
Switching times < 8ms.
Knurled contacts to provide lower ohmic resistance thanks to the multiple electrical connection points: extended electrical life expectancy of the component, optimal performance for strongly inductive DC loads and for very low loads, such as in the case of interface signals.
High breaking capacity for controlling very heavy duty DC loads, also with intensive switching frequency.
Elevated production versatility. Nominal voltage available from 12 to 220VDC/440VAC, with multiple operating ranges. Facility to adapt the products to meet specific application requirements.
The typical application sectors are among the most demanding, such as electricity generating stations, electrical transformer stations, fixed equipment for railways, or industries using continuous production processes (chemical and petrochemical, rolling mills, cement works, etc.)
- EN 61810-1, EN 61810-2, EN 61810-7 Electromechanical elementary relays
- EN 60695-2-10 Fire hazard testing
- EN 50082-2 Electromagnetic compatibility
- EN 60529 Degrees of protection provided by enclosures
Download technical drawings 2D/3D
LOGIN / REGISTRATION- Connection: Front
- Terminal type: Screw
- Mounting: Panel /DIN Rail
- Wire max (mm2): 2 x 2.5
- Operating temperature: -25…+55°C
Details
- Connection: Rear
- Terminal type: Screw
- Mounting: Panel
- Wire max (mm2): 2 x 2.5
- Operating temperature: -25…+55°C
Details
- Connection: Rear
- Terminal type: Double faston
- Mounting: Panel
- Wire max (mm2): 2 x 2.5
- Operating temperature: -25…+55°C
Details