Latching

Relay with 2 latched contact positions. The contacts change state with an electrical pulse supplied by one of the 2 power coils. To restore the starting position of the contacts, the other coil must be powered.

Model Contacts Nominal
Current
Coil input Note Classification
OKBA

4

10

DC or AC 8 C/O as option Control relay, 4 C/O contacts, STF IFS TE 143A
BAS8

8

10

DC or AC Control relay, 8 C/O contacts, STF IFS TE 143A

Instantaneous, monostable

The contacts change position instantaneously when the relay is powered and return instantaneously to their initial position when power is shut off.

Model Contacts Nominal
Current
Coil input Note Classification
POKS

2

10

DC or AC Compact, magnetic arc blow-out Control relay, Signal relay, 2 NO contacts, STF IFS TE 143A
BIPOKS

4

10

DC or AC Compact, magnetic arc blow-out Signal relay, 4 C/O contacts, STF IFS TE 143A
TRIPOKS

6

10

DC or AC Compact, magnetic arc blow-out Signal relay, 6 C/O contacts, STF IFS TE 143A
OKSFC

4

8

12

10

DC or AC 8 and 12 C/O as option, 100.000.000 operations Control relay, 4 C/O contacts, STF IFS TE 143A

Time delayed, pick-up, drop-out, logic

The contacts change status with time delay T with respect to the energization or de-energization of the relay input circuit. Logical function relays can be used for various functions, including CYCLIC, ONE-SHOT, etc.

Model Contacts Nominal
Current
Coil input Note Classification
TM4E TMS4E

4

5

10

DC or AC Wide scale, Delay ON Signal relay, 4 C/O contacts, STF IFS TE 143A
TM4R TMS4R

4

5

10

DC or AC Wide scale, Delay OFF Signal relay, 4 C/O contacts, STF IFS TE 143A
OKTF

4

10

DC or AC Delay OFF, no power supply Control relay, 2 C/O contacts, STF IFS TE 143A
RMTZ04

4

10

DC RFI (Italian Railway) approved, T2 type relay T2 relay, timed, STF IFS TE 143A
RMTZ05

4

10

DC RFI (Italian Railway) approved, T1 type relay T1 relay, timed, STF IFS TE 143A
RMTZ07

4

10

DC RFI (Italian Railway) approved, T3 type relay T3 relay, timed, STF IFS TE 143A

Measurement

The contacts change status for a defined input power value.

Model Contacts Nominal
Current
Coil input Note Classification
MAMF12

2

10

DC Insulation between input and contact: 12kV Auxiliary relay, high insulation
MAVF1X

2

10

DC Measuring relay, insulation 15kV Voltage measuring relay, MIN/MAX thresholds, STF TE 155