AMRA LINE

Trip relay, monostables and latching

Trip relays, with reduced switching times (e.g. <10ms) compared to standard relays (e.g. < 20ms).

Model Contacts Nominal
Current
Coil input Heavy duty use Rolling Stock Note
RV LV16

6

5

DC Ultra Fast-acting (trip relay) < 6ms, monostable

Forcibly guided contacts

The contacts are mechanically linked. These relays use special features to ensure the make contacts (normally open) cannot assume the same state as the break contacts (normally-closed).

Model Contacts Nominal
Current
Coil input Heavy duty use Rolling Stock Note
RCG

2

10

DC or AC Forcibly guided contacts, weld-no-transfer, EN61810-3 type A
RDG

4

10

DC or AC Forcibly guided contacts, weld-no-transfer, EN61810-3 type A
RGG

4

12

DC or AC Forcibly guided contacts, weld-no-transfer, EN61810-3 type A, high breaking capacity
RGK

4

12

DC or AC Timed with forcibly guided contacts, weld-no-transfer, EN61810-3 type A, high breaking capacity
RMGX

8

10

DC or AC Forcibly guided contacts, weld-no-transfer, EN61810-3, type A, high breaking capacity

Latching

Relay with 2 latched contact positions. The contacts change state with an electrical pulse supplied by one of the 2 power coils. To restore the starting position of the contacts, the other coil must be powered.

Model Contacts Nominal
Current
Coil input Heavy duty use Rolling Stock Note
OKBA

4

10

DC or AC 8 C/O as option
BAS8

8

10

DC or AC

Instantaneous, monostable

The contacts change position instantaneously when the relay is powered and return instantaneously to their initial position when power is shut off.

Model Contacts Nominal
Current
Coil input Heavy duty use Rolling Stock Note
POK

2

5

DC or AC Compact, magnetic arc blow-out
POKS

2

10

DC or AC Compact, magnetic arc blow-out
BIPOK

4

5

DC or AC Compact, magnetic arc blow-out
BIPOKS

4

10

DC or AC Compact, magnetic arc blow-out
TRIPOK

6

5

DC or AC Compact, magnetic arc blow-out
TRIPOKS

6

10

DC or AC Compact, magnetic arc blow-out
QUADRIPOK

8

10

DC or AC Compact, magnetic arc blow-out
ESAPOK

12

10

DC or AC Compact, magnetic arc blow-out
OK

4

8

12

10

DC or AC 8 and 12 C/O as option, available in Italian Navy version, 100.000.000 operatioons
OKS

4

8

12

10

DC or AC 8 and 12 C/O as option, 100.000.000 operations, magnetic arc blow-out
OKFC

4

8

12

10

DC or AC 8 and 12 C/O as option, 100.000.000 operations, low consumption
OKSFC

4

8

12

10

DC or AC 8 and 12 C/O as option, 100.000.000 operations
OKUIC

4

10

DC or AC TRENITALIA approved, 100.000.000 operations
OKSCD

4

10

DC or AC Very high breaking capacity, 100.000.000 operations
OKSGcCd

4

10

DC or AC Very high breaking capacity, contact gap 4mm, 100.000.000 operations
OKB184

4

10

DC K3 compliant
FOKB

4

13

DC Double break, NF-F 62002 compliant

Time delayed, pick-up, drop-out, logic

The contacts change status with time delay T with respect to the energization or de-energization of the relay input circuit. Logical function relays can be used for various functions, including CYCLIC, ONE-SHOT, etc.

Model Contacts Nominal
Current
Coil input Heavy duty use Rolling Stock Note
TMM2

4

10

DC or AC Multifunction relay, 10 functions, 2 timed + 2 inst. contacts
TMM4

4

10

DC or AC Multifunction relay, 10 functions, 4 timed contacts
TM2E TMS2E

4

5

10

DC or AC Wide scale, Delay ON (2) + INST (2)
TM4E TMS4E

4

5

10

DC or AC Wide scale, Delay ON
TM2R TMS2R

4

5

10

DC or AC Wide scale, Delay OFF (2) + INST (2)
TM4R TMS4R

4

5

10

DC or AC Wide scale, Delay OFF
TOKE

4

10

DC or AC Delay ON, 100.000.000 operations
TOKR

4

10

DC or AC Delay OFF, 100.000.000 operations
OKTF

4

10

DC or AC Delay OFF, no power supply
OKTA

4

5

DC or AC Delay ON
OKTR

4

5

DC or AC Delay OFF
OKRE

4

5

DC or AC Delay ON
OKRR

4

5

DC or AC Delay OFF
UTME DC Static time delay unit, delay ON
UTMR DC Static time delay unit, delay OFF
TOK-L

4

5

DC or AC Flashers, 100.000.000 operations
OKRE-L

4

5

DC or AC Flashers
TOK-FP

4

5

DC or AC One-shot, 100.000.000 operations
OKRE-FP

4

5

DC or AC One-shot
CLE

4

5

DC or AC Flashers, fixed time
RGK

4

12

DC or AC Timed with forcibly guided contacts, weld-no-transfer, EN61810-3 type A, high breaking capacity

Measurement

The contacts change status for a defined input power value.

Model Contacts Nominal
Current
Coil input Heavy duty use Rolling Stock Note
MOK-V2

2

5

DC or AC Measuring relay, voltage threshold
OKPH

2

5

AC Sequence & detection phase
MOK-PH2

2

5

AC Sequence & detection phase